1 (Table of Contents) - 2-3-4-5-6
- Sensitivity. The DrugCheck 5
TM detects drugs of abuse and
their major metabolites in urine at concentrations equal to or
greater than the cut-off level for the specific drug, which is
suggested by the U.S. Substance Abuse and Mental Health Services
Administration (SAMHSA) for the immunoassay method.
- Specificity. A study was conducted
with the DrugCheck 5 to determine the cross-reactivity of drug-related
compounds with the test. Substances listed in Table I produced
results approximately equivalent to the cutoff levels. A separate
study was conducted to determine the cross-reactivity of non-related
compounds with the test at concentrations much higher than normally
found in the urine of people using or abusing them. No cross reactivity
was detected with the substances listed in Table II.
Back to
Top
Table I: Concentrations of
drug-related compounds showing positive response approximately equivalent
to the cut-off set for the test:
The following Amphetamine-related
substances yield positive results for Amphetamine:
| d-Amphetamine |
1,000 ng/ml |
Thyramine |
100,000 ng/ml |
| I-Amphetamine |
25,000 ng/ml |
(+)3,4 MethylenedioxyAmphetamine |
600 ng/ml |
| d,I-Amphetamine |
1,000 ng/ml |
(+)Pseudophedrine |
100,000 ng/ml |
| (+)Phenylpropanolamine |
50,000 ng/ml |
(+)Ephedrine |
250,000 ng/ml |
| B-Phenylthylamine |
90,000 ng/ml |
Back to
Top
The following Marijuana-related
substances yield positive results for Marijuana:
| 11-Nor-D 8-THC-9-COOH |
50 ng/ml |
D-9-THC |
4 mg/ml |
| 11-Nor-D 9-THC-9-COOH |
50 ng/ml |
Cannabinol |
10 mg/ml |
| D-8-THC |
1 mg/ml |
11-hydroxy-D-9-THC |
10 mg/ml |
Back to
Top
The following Cocaine-related
substances yield positive results for Cocaine:
| Benzoylecgonine |
300 ng/ml |
| Cocaine |
300 ng/ml |
| Isoxsurpine |
1,500 ng/ml |
Back to
Top
The following Opiates-related
substances yield a positive result for Opiates:
| Morphine |
300 ng/ml |
Oxycodone |
1,000 ng/ml |
| Morphine-3-b-D-Glucuronide |
300 ng/ml |
Levorphanol |
600 ng/ml |
| Codeine |
300 ng/ml |
Naloxone |
1,000 ng/ml |
| Heroin |
300 ng/ml |
Thebaine |
1,500 ng/ml |
| Norcodein |
2,000 ng/ml |
Imipramine |
50,000 ng/ml |
| Nalorphine |
300 ng/ml |
Atropine |
100,000 ng/ml |
| Hydrocodone |
500 ng/ml |
Meperidine |
100,000 ng/ml |
| Hydromorphone |
300 ng/ml |
Ranitidine |
100,000 ng/ml |
Back to Top
The following Phencyclidine (PCP)-related substances
yield positive results for Phencyclidine (PCP):
| (+) 3, 4-MethylenedioxyPhencyclidine (PCP) (MDMA,
Ecstasy) |
500 ng/ml |
| d-Amphetamine |
50,000 ng/ml |
| (+) 3, 4-Methylenedioxyamphetamine (MDA) |
50,000 ng/ml |
| (+) Phencyclidine (PCP) |
50,000 ng/ml |
| D, 1-amphetamine |
10,000 ng/ml |
| Pseudoephedrine |
1,000 ng/ml |
| Ephedrine |
25,000 ng/ml |
Back to Top